Table 1

Mean values of exercise testing and their limits of agreement between two treadmill protocols (Bruce and RIS)

Exercise protocolEndurance time (mins)Maximal heart rate (beats/min)VO2max (ml/min)VAT (ml/min)OUESRER at peak exercise
Bruce13.5 (1.9)197 (8)1690 (860)1160 (700)1790 (880)1.08 (0.08)1-150
RIS5.0 (1.9)194 (6)1720 (670)1160 (580)1790 (870)1.12 (0.12)
Mean (SD) of difference−3 (7)37 (190)0.4 (180)−6 (160)0.04 (0.07)
Limit of agreement+11 (+5%) to
−17 (−8%)
+410 (+24%) to −340 (−20%)+360 (+31%) to −360 (−31%)+310 (+17%) to −320 (−18%)+0.18 (+16%) to
−0.10 (−9%)
  • Data are expressed as mean (SD). Limits of agreement are expressed as absolute values and the percentages of the mean values of the two sessions in parentheses.

  • 1-150 p < 0.05 between the two protocols.

  • OUES, oxygen uptake efficiency slope; RER, the respiratory exchange ratio; RIS, rapidly increasing staged protocol; VAT, oxygen uptake at the ventilatory anaerobic threshold; VO2max, maximal oxygen uptake.