PT - JOURNAL ARTICLE AU - Beddis, I R AU - Silverman, M TI - Hypoxia in a neonate caused by intermittent positive pressure ventilation. AID - 10.1136/adc.55.5.403 DP - 1980 May 01 TA - Archives of Disease in Childhood PG - 403--405 VI - 55 IP - 5 4099 - http://adc.bmj.com/content/55/5/403.short 4100 - http://adc.bmj.com/content/55/5/403.full SO - Arch Dis Child1980 May 01; 55 AB - A newborn baby receiving mechanical ventilation was noted to have an extremely variable degree of hypoxia, despite the administration of 100% oxygen. The hypoxia was relieved rapidly when mechanical ventilation was withdrawn.