PT - JOURNAL ARTICLE AU - Sinniah, D AU - Omar, A TI - Quantitation of digital clubbing by shadowgram technique. AID - 10.1136/adc.54.2.145 DP - 1979 Feb 01 TA - Archives of Disease in Childhood PG - 145--146 VI - 54 IP - 2 4099 - http://adc.bmj.com/content/54/2/145.short 4100 - http://adc.bmj.com/content/54/2/145.full SO - Arch Dis Child1979 Feb 01; 54 AB - Finger clubbing was quantified from the magnified silhouette of the right index finger in controls and patients with clubbing, using a simple shadowgram technique. There was good correlation between clinical assessment and measurement of both the profile angle and the hyponychial angle. The hyponychial angle appeared to be a more accurate indicator of clubbing than the profile angle.