Article Text

other Versions

Download PDFPDF
Diagnostic accuracy of the D-dimer in children
  1. Jessica Kanis,
  2. Cassandra L Hall,
  3. Jonathan Pike,
  4. Jeffrey A Kline
  1. Department of Emergency Medicine, Indiana University School of Medicine, Indianapolis, Indiana, USA
  1. Correspondence to Dr Jeffrey A Kline, Department of Emergency Medicine, Indiana University School of Medicine, Indianapolis, IN 46202, USA; jefkline{at}iu.edu

Abstract

Background We sought to measure the diagnostic accuracy of D-dimer in children with suspected pulmonary embolism (PE).

Methods We queried our electronic medical record for quantitative D-dimer values obtained in all children ages 5–17 over 10 years in our 10-hospital system. Patients who had a D-dimer obtained in the evaluation of PE underwent supervised chart review to extract baseline demographics (age, sex, ethnicity), medical history, laboratory data and imaging results. PE was confirmed by imaging positive for deep vein thrombosis (DVT) or PE and excluded by imaging or no DVT or PE diagnosis within 90 days.

Results Over a 10-year period, we identified 13 792 orders for D-dimer testing in 2554 unique patients. Chart review indicated that 526 (20.6%) unique patients had D-dimer testing performed in the evaluation of PE (Cohen’s kappa=0.95, 95% CI 0.85 to 1.0). Most D-dimers (465/526, 88%) were ordered in children aged >12 years. Of these 526 children, 34 (6.4%, 95% CI) had a criterion standard positive for new or recurrent PE. The mean D-dimer value was 2104±1394 ng/mL in the 34/34 PE+ children and 586±962 ng/mL in PE− children with a sensitivity of 34/34 (100%, 89% to 100%) and a specificity of 290/492 (58%, 54% to 63%). The area under the receiver operating characteristic curve was 0.90 ((0.9)87–0.94).

Conclusions D-dimer is currently ordered in children for suspected PE in the emergency care setting, mostly in teenagers. The observed lower limit 95% CIs of 89% and 54% for diagnostic sensitivity and the specificity, respectively, suggest if used in patients with low-clinical probability, a normal D-dimer can safely exclude PE in children.

  • venous thromboembolism
  • pulmonary embolism
  • adolescence
  • diagnosis
  • d-dimer

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Contributors JK, JAK: study design, protocol writing, funding, data collection, analysis, manuscript preparation. CLH, JP: protocol writing, data collection, analysis, manuscript preparation.

  • Funding This study is funded by Eli Lilly Foundation Physician Scientist Award.

  • Competing interests Mallinckrodt, NIH, Roche Diagnostica-Grant/research support Janssen Pharmaceuticals-Consultant Indiana Lysis Technlogies, LLC-Founder

  • Provenance and peer review Not commissioned; externally peer reviewed.

Linked Articles