Article Text

Nocturnal oxygen saturation profiles of healthy term infants
  1. Philip Ian Terrill1,
  2. Carolyn Dakin2,
  3. Ian Hughes3,
  4. Maggie Yuill2,
  5. Chloe Parsley2
  1. 1School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Queensland, Australia
  2. 2Department of Respiratory and Sleep Medicine, The Mater Children's Hospital, South Brisbane, Queensland, Australia
  3. 3Australasian Paediatric Endocrine Group, Mater Medical Research Institute, Brisbane, Queensland, Australia
  1. Correspondence to Dr Philip Terrill, School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD 4072, Australia; p.terrill{at}uq.edu.au

Abstract

Objective Pulse oximetry is used extensively in hospital and home settings to measure arterial oxygen saturation (SpO2). Interpretation of the trend and range of SpO2 values observed in infants is currently limited by a lack of reference ranges using current devices, and may be augmented by development of cumulative frequency (CF) reference-curves. This study aims to provide reference oxygen saturation values from a prospective longitudinal cohort of healthy infants.

Design Prospective longitudinal cohort study.

Setting Sleep-laboratory.

Patients 34 healthy term infants were enrolled, and studied at 2 weeks, 3, 6, 12 and 24 months of age (N=30, 25, 27, 26, 20, respectively).

Interventions Full overnight polysomnography, including 2 s averaging pulse oximetry (Masimo Radical).

Main outcome measurements Summary SpO2 statistics (mean, median, 5th and 10th percentiles) and SpO2 CF plots were calculated for each recording. CF reference-curves were then generated for each study age. Analyses were repeated with sleep-state stratifications and inclusion of manual artefact removal.

Results Median nocturnal SpO2 values ranged between 98% and 99% over the first 2 years of life and the CF reference-curves shift right by 1% between 2 weeks and 3 months. CF reference-curves did not change with manual artefact removal during sleep and did not vary between rapid eye movement (REM) and non-REM sleep. Manual artefact removal did significantly change summary statistics and CF reference-curves during wake.

Conclusions SpO2 CF curves provide an intuitive visual tool for evaluating whether an individual's nocturnal SpO2 distribution falls within the range of healthy age-matched infants, thereby complementing summary statistics in the interpretation of extended oximetry recordings in infants.

  • Respiratory
  • Sleep
  • Measurement
  • Technology

This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 3.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/3.0/

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Supplementary materials

  • Supplementary Data

    This web only file has been produced by the BMJ Publishing Group from an electronic file supplied by the author(s) and has not been edited for content.

    Files in this Data Supplement: