A low cost, colour coded, hand held spring scale accurately categorises birth weight in low resource settings

L C Mullany1, G L Darmstadt2, P Coffey3, S K Khatry4, S C LeClerq4, J M Tielsch1

1 Department of International Health, Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD, USA
2 Saving Newborn Lives, Save the Children-US (SC), 2000 M Street, NW, Suite 500, Washington DC, USA
3 Program for Appropriate Technology in Health (PATH), 1455 NW Leary Way, Seattle, USA
4 Nepal Nutrition Intervention Project, Sarlahi (NNIPS) PO Box 335, Katmandu, Nepal

Correspondence to:
Dr Gary L Darmstadt
Department of International Health, E-8153, Bloomberg School of Public Health, Johns Hopkins University, 615 N. Wolfe Street, Baltimore, MD 21205-2103, USA; gdarmsta{at}jhsph.edu

Aims: To determine the accuracy of a low cost, spring calibrated, hand held scale in classifying newborns into three weight categories (>=2500 g, 2000–2499 g, <2000 g).

Methods: The test device was compared to a gold standard digital baby scale with precision to 2 g. In Sarlahi district, Nepal, 1890 newborns were eligible for the study. Measurements were collected for both the test device and the digital scale from 1820 (96.3%) newborns.

Results: The overall low birth weight (LBW) prevalence rate for the gold standard digital scale was 28.1% (511/1820). Sensitivity (93.7%) and specificity (97.6%) of the test device was high compared to LBW classifications based on digital weight measurements. Classification of infants into the <2000 g category was 5.0% and 4.7% for the gold standard and test device, respectively. Sensitivity and specificity of the test device in identifying infants <2000 g was 87.8% and 99.6%, respectively. Positive predictive values were high (>91%) for both weight categories

Conclusions: This low cost, simple-to-use device classified infants into weight categories with a high degree of consistency and accuracy that exceeds that of surrogate measures. This new device is useful for identifying and targeting life saving interventions for LBW, high risk infants in settings where infants are born in the home and conventional weighing scales are unavailable.

Keywords: low birth weight; neonatal; scale; sensitivity; specificity; validity


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Latest from ADC

 

ADC is co-owned by the RCPCH and is the official journal of the European Academy of Paediatrics

BMJ Careers - Latest Paediatrics and Paediatric Surgery Jobs

Paediatrics and Paediatric Surgery Jobs