A non-electrostatic spacer for aerosol delivery.

H Bisgaard, J Anhøj, B Klug, E Berg

Department of Paediatrics, National University Hospital, Copenhagen, Denmark.

A pear shaped non-electrostatic spacer, composed of steel with a volume of 250 ml and equipped with a facemask containing integrated inlet and outlet valves for inspiration and expiration, was compared with three plastic spacers. The plastic spacers were primed with repeated puffs from a budesonide pressurised metered dose inhaler (p-MDI) to minimise the electrostatic charge on the plastic. The procedure prolonged the half life (t1/2) of the aerosol in the Nebuhaler from nine to 32 seconds. A normal cleaning procedure reduced the aerosol t1/2 back to baseline. The t1/2 of the aerosol in the metal spacer was 27 seconds and independent of the use of p-MDI. In vitro the maximum dose of budesonide from a p-MDI, expressed as a percentage of the nominal dose, was 56% from the non-electrostatic spacer, 61% from the Nebuhaler, 45% from the Babyhaler, and 30% from the AeroChamber. In 124 children, age 6 months to 6 years, suspected to have asthma the non-electrostatic spacer delivered a mean total dose of budesonide aerosol of 39% of the nominal dose, which was significantly higher than the Babyhaler (28%), the Nebuhaler (21%), and the AeroChamber (19%). These differences were most pronounced in children younger than 4 years. The improved dose delivery from the small volume non-electrostatic spacer is probably related to the non-electrostatic spacer material and the valves which assured unidirectional airflow from the spacer without adding any dead space in the inspiratory channel. The non-electro-static spacer should improve the cost effectiveness of aerosol treatment and, as the counteracting effects of proming and recharging of the plastic from cleaning are avoided, should deliver a more reliable dose.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Bisgaard, H., Hermansen, M. N., Buchvald, F., Loland, L., Halkjaer, L. B., Bonnelykke, K., Brasholt, M., Heltberg, A., Vissing, N. H., Thorsen, S. V., Stage, M., Pipper, C. B. (2007). Childhood Asthma after Bacterial Colonization of the Airway in Neonates. NEJM 357: 1487-1495 [Abstract] [Full Text]  
  • Kohler, D., Haidl, P., Dellweg, D., Bont, L., Kimpen, J. L.L., Ermers, M. J.J., Baraldi, E., Filippone, M., Guilbert, T., Martinez, F. D., Szefler, S. J., the Childhood Asthma Research and Education (CARE), , Bisgaard, H., Gold, D. R., Fuhlbrigge, A. L. (2006). Inhaled corticosteroids and children.. NEJM 355: 624-624 [Full Text]  
  • (2005). Inhalation devices. CMAJ 173: S39-S45 [Full Text]  
  • Amirav, I, Mansour, Y, Tiosano, T, Chamny, S, Chirurg, S, Oren, S, Grossman, Z, Kahana, L, Kahan, E, Newhouse, M T (2003). Safety of inhaled corticosteroids delivered by plastic and metal spacers. Arch. Dis. Child. 88: 527-528 [Abstract] [Full Text]  
  • Amirav, I., Newhouse, M. T. (2001). Aerosol Therapy With Valved Holding Chambers in Young Children: Importance of the Facemask Seal. Pediatrics 108: 389-394 [Abstract] [Full Text]  
  • Dompeling, E, Oudesluys-Murphy, A M, Janssens, H M, Hop, W, Brinkman, J G, Sukhai, R N, de Jongste, J C (2001). Randomised controlled study of clinical efficacy of spacer therapy in asthma with regard to electrostatic charge. Arch. Dis. Child. 84: 178-182 [Abstract] [Full Text]  
  • ØJ, J. A., THORSSON, L., BISGAARD, H. (2000). Lung Deposition of Inhaled Drugs Increases with Age. Am. J. Respir. Crit. Care Med. 162: 1819-1822 [Abstract] [Full Text]  
  • Berridge, M. S., Lee, Z., Heald, D. L. (2000). Pulmonary Distribution and Kinetics of Inhaled [11C]Triamcinolone Acetonide. JNM 41: 1603-1611 [Abstract] [Full Text]  
  • Zar, H J, Weinberg, E G, Binns, H J, Gallie, F, Mann, M D (2000). Lung deposition of aerosol---a comparison of different spacers. Arch. Dis. Child. 82: 495-498 [Abstract] [Full Text]  
  • Mandelberg, A., Tsehori, S., Houri, S., Gilad, E., Morag, B., Priel, I. E. (2000). Is Nebulized Aerosol Treatment Necessary in the Pediatric Emergency Department?. Chest 117: 1309-1313 [Abstract] [Full Text]  
  • (1999). Inhalation devices and propellants. CMAJ 161: s44-50 [Full Text]  
  • BISGAARD, H. (1997). Automatic Actuation of a Dry Powder Inhaler into a Nonelectrostatic Spacer. Am. J. Respir. Crit. Care Med. 157: 518-521 [Abstract] [Full Text]  
  • HAYDEN, M. J., PETAK, F., HANTOS, Z., HALL, G., SLY, P. D. (1997). Using Low-frequency Oscillation to Detect Bronchodilator Responsiveness in Infants. Am. J. Respir. Crit. Care Med. 157: 574-579 [Abstract] [Full Text]  
  • Bisgaard, H. (1996). Drug delivery from inhaler devices. BMJ 313: 895-896 [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Latest from ADC

 

ADC is co-owned by the RCPCH and is the official journal of the European Academy of Paediatrics

BMJ Careers - Latest Paediatrics and Paediatric Surgery Jobs

Paediatrics and Paediatric Surgery Jobs