Influence of spacer device on drug delivery to young children with asthma.
Department of Paediatrics, Kolding Hospital, Denmark.
The budesonide dose delivered to the patient from three different spacer devices (Nebuhaler = 750 ml, Aerochamber = 140 ml, and Babyspacer = 260 ml) was assessed by measuring the budesonide dose deposited on a filter inserted between the spacer outlet and the mouth of the patient. Twenty children aged 10-25 months were given a single dose of 200 micrograms budesonide from each spacer device in a randomised crossover study. All spacers had a facemask attached and a one way valve system. The children breathed through the inhalation system for 30 seconds. Furthermore, the minute ventilation of the children through a tightly fitting facemask was measured. The filter dose of budesonide was significantly lower after Aerochamber treatment (39.4 micrograms, range 19-67 micrograms) than after Nebuhaler (53.5 micrograms, range 34-88 micrograms) and Babyspacer (55.5 micrograms, range 39-76 micrograms) treatment. The minute ventilation of the children varied from 1.4 l/min to 7.0 l/min (mean 5.0 l/min). This was sufficient to empty all spacers within the 30 seconds of inhalation. It is concluded that spacer volume does not seem to be so important for children aged 10-25 months as long as spacers with a volume lower than 750 ml are used.
Relevant Article
- Commentary
- Michael Silverman
Arch. Dis. Child. 1994 71: 219-220.[PDF]
This article has been cited by other articles:
-
Wright, J, Brocklebank, D, Ram, F
(2002). Inhaler devices for the treatment of asthma and chronic obstructive airways disease (COPD). Qual Saf Health Care
11: 376-382
[Abstract] [Full Text] -
Amirav, I., Newhouse, M. T.
(2001). Aerosol Therapy With Valved Holding Chambers in Young Children: Importance of the Facemask Seal. Pediatrics
108: 389-394
[Abstract] [Full Text] -
Adams, R. J., Fuhlbrigge, A., Finkelstein, J. A., Lozano, P., Livingston, J. M., Weiss, K. B., Weiss, S. T.
(2001). Use of Inhaled Anti-inflammatory Medication in Children With Asthma in Managed Care Settings. Arch Pediatr Adolesc Med
155: 501-507
[Abstract] [Full Text] -
MELLON, M., LEFLEIN, J., WALTON-BOWEN, K., CRUZ-RIVERA, M., FITZPATRICK, S., SMITH, J. A.
(2000). Comparable Efficacy of Administration with Face Mask or Mouthpiece of Nebulized Budesonide Inhalation Suspension for Infants and Young Children with Persistent Asthma. Am. J. Respir. Crit. Care Med.
162: 593-598
[Abstract] [Full Text] -
O'CALLAGHAN, C., BARRY, P. W
(2000). How to choose delivery devices for asthma. Arch. Dis. Child.
82: 185-187
[Full Text] -
(2000). Inhaler devices for asthma. DTB
38: 9-14
[Abstract] [Full Text] -
Agertoft, L, Andersen, A, Weibull, E, Pedersen, S
(1999). Systemic availability and pharmacokinetics of nebulised budesonide in preschool children. Arch. Dis. Child.
80: 241-247
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.