Illuminance of neonatal units.
Department of Ophthalmology, University of Birmingham, Birmingham and Midland Eye Hospital.
We have measured the illuminance (brightness) of seven neonatal units during both the day and the night. When the units were lit solely by fluorescent tubes the mean illuminance was 348 lux (range 192-690). During the day the mean illuminance was 470 lux (range 236-905). The high dependency regions in four of the seven units were significantly brighter than the corresponding low dependency nurseries at all times. In two of these units there is a policy of reducing the amount of artificial light in the low dependency areas at night, and in these the normal mean illuminance was 50 lux. We have measured the general levels of illumination to which a neonate might be exposed; the ocular exposure to light of a neonate depends, however, on both physical and biological factors and more research is required before an accurate estimate can be made.
This article has been cited by other articles:
-
Lasky, R. E., Williams, A. L.
(2009). Noise and Light Exposures for Extremely Low Birth Weight Newborns During Their Stay in the Neonatal Intensive Care Unit. Pediatrics
123: 540-546
[Abstract] [Full Text] -
Bullough, J., Rea, M.S.
(1996). Lighting for neonatal intensive care units: Some critical information for design. Lighting Research and Technology
28: 189-198
[Abstract]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.